ABB Overload Relay
ABB Overload Relay

ABB Overload Relay

MOQ : 100 Units

ABB Overload Relay Specification

  • Power Consumption
  • Low Decibel-milliwatt (dBm)
  • Contact Material
  • Silver Alloy
  • Protect Feature
  • Other
  • Ambient Temperature
  • -25C ~ +55C Celsius (oC)
  • Contact Resistance
  • 50 m Milliohm (m)
  • Working Temperature
  • -20C ~ +60C Celsius (oC)
  • Contact Form
  • 1 NO + 1 NC
  • Mechanical Life
  • Over 1 million operations Hours
  • Coil Power
  • Not Applicable (Thermal Type)
  • Coil Voltage
  • Not Applicable (Thermal Type) Milliamperes (mA)
  • Dielectiric Strength
  • 2.5 kV, 50/60 Hz for 1 min Kilopascals (KPa)
  • Product Type
  • Overload Relay
  • Insulation Resistance
  • > 100 M at 500 V DC
  • Theory
  • Other
  • Usage
  • Motor protection, overload protection in control circuits
  • Contact Load
  • Other
  • Operate Time
  • 30 ms Months
  • Terminal Type
  • Other
  • Rated Voltage
  • 690 V AC Volt (V)
  • Supply Terminal
  • Three Pole
  • Size
  • Color
  • Grey and Black
  • Dimension (L*W*H)
  • Approx. 45 x 75 x 70 mm Meter (m)
  • Weight
  • Approx. 150 g GSM (gm/2)
  • Mounting Type
  • Direct/Panel Mounting
  • Storage Temperature
  • -40C to +70C
  • Reset Type
  • Manual/Automatic
  • Relay Type
  • Bimetallic Thermal relay
  • Application
  • Industrial Automation, Motor Starter Circuits
  • Degree of Protection
  • IP20
  • Short Circuit Protection
  • With recommended fuse
  • Frequency
  • 50/60 Hz
  • Trip Class
  • Class 10A
  • Adjustment Range
  • 0.1 - 16 A (Model dependent)
 

ABB Overload Relay Trade Information

  • Minimum Order Quantity
  • 100 Units
  • FOB Port
  • KOLKATA
  • Payment Terms
  • Cash Against Delivery (CAD), Cash Advance (CA), Cash in Advance (CID), Cheque
  • Supply Ability
  • 5000 Units Per Month
  • Delivery Time
  • 7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Domestic Market
  • Odisha, Assam, Arunachal Pradesh, Chhattisgarh, Nagaland, Sikkim, Tripura, East India, Mizoram, Meghalaya, Manipur, Bihar, Jharkhand, West Bengal
 

ABB Overload Relay About



Unlock optimum motor safety with ABB's Paragon Bimetallic Thermal Overload Relay, featuring a special rate and exclusive price cut during our ongoing promotion. This sterling device guarantees reliable overload and phase failure protection for motor starter circuits in industrial automation. With adaptable adjustment ranges (0.1-16A, model specific), direct or panel mounting, and IP20-rated durability, it stands as a hallmark of control. Automatic/manual reset, robust screw terminals, and a mechanical life of over one million operations ensure long-lasting performance. Trust ABB's benchmark for overload protection and precision engineering.

ABB Overload Relay: Usage, Applications & User Advantages

ABB Overload Relays are engineered for robust protection in industrial automation and motor starter circuits, making them essential for manufacturers, maintenance teams, and automation integrators. Suited for both overload and phase failure protection, these relays enhance safety and prolong equipment lifespan. With trip class 10A and swift operate time, they ensure motors operate within optimum parameters, reducing downtime and maintenance costs. Companies benefit from their durability, easy installation, and versatility across diverse control panels.


FOB Port, Payment Terms, and Sample Requests for ABB Overload Relay

Obtain your sterling ABB Overload Relay via our India FOB port with flexible payment terms tailored to your needs. Request a detailed quotation or proposal amount to streamline your procurement process. Upon agreed terms, prompt handover is ensured for seamless supply chain integration. Product samples are available upon request, enabling you to evaluate relay quality before making full-scale acquisition. Our supply and trader expertise guarantees a smooth purchasing experience for your industrial requirements.


FAQ's of ABB Overload Relay:


Q: How does the ABB Overload Relay benefit industrial motor starter circuits?

A: The relay offers superior overload, phase failure, and temperature protection, ensuring motors remain safeguarded against faults in industrial motor starter applications, thereby reducing equipment failure and downtime.

Q: What is the process for mounting the ABB Overload Relay?

A: This relay supports direct and panel mounting, allowing for flexible installation onto control panels or directly onto equipment, using standard screw terminals and secure connections.

Q: When should you choose the manual or automatic reset type?

A: Use the manual reset for critical applications that require operator intervention for safety, and select the automatic reset when continuous operation and self-restoration are vital.

Q: Where can I request a quotation and what payment terms are available?

A: Quotations and proposal amounts can be requested from our Indian supply or trading contacts, with flexible payment terms designed to meet diverse procurement needs.

Q: How does the recommended short circuit protection work with the relay?

A: The ABB Overload Relay should be paired with the recommended fuse to deliver optimum short circuit protection, ensuring comprehensive safety for connected motors and circuits.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Over load Relay Category

L&T Overload Relay

L&T Overload Relay

Price 4000.00 INR / Unit

Minimum Order Quantity : 50 Units

Rated Voltage : 415V AC Volt (V)

Usage : Motor Protection

Ambient Temperature : 20C to +55C Celsius (oC)

Working Temperature : 10C to +50C Celsius (oC)

L&T Thermal Overload Relay

L&T Thermal Overload Relay

Price 900 INR / Unit

Minimum Order Quantity : 100 Units

Rated Voltage : 460 V Volt (V)

Usage : Motor Protection

Ambient Temperature : Up to 55 Degree Celsius (oC)

Working Temperature : 5C to 55C Celsius (oC)

Siemens Overload Relay

Siemens Overload Relay

Minimum Order Quantity : 1 Unit

Rated Voltage : 690 V AC Volt (V)

Usage : Motor protection, Overload protection

Ambient Temperature : 20C to +60C Celsius (oC)

Working Temperature : 10C to +55C Celsius (oC)

350V Schneider Overload Relay

350V Schneider Overload Relay

Price 1100 INR / Piece

Minimum Order Quantity : 100 Pieces

Rated Voltage : 350 V Milliamperes (mA)

Usage : Electric Use

Ambient Temperature : 20 to +50 C Rankine

Working Temperature : 20 to +50 C Fahrenheit (oF)